Various : installing full avr version : REPLY

Thanks a lot, got it.

View Article


BASCOM-AVR : Chip45 Crumb128 Module Programmer : REPLY

Hi People Got it sorted Cheers

View Article


BASCOM-AVR : please help with my first project : REPLY

The Ganssle article on debouncing switches can be found [url=http://www.ganssle.com/debouncing.htm] HERE [/url]. JC

View Article

BASCOM-AVR : Any limit to length in Crc16uni function? : NEWTOPIC

I'm using Crccalc = Crc16uni(buffer1(4) , 1024 , 0 , &H1021 , 0 , 0) to calculate Xmodem-1K CRC, doesn't get the correct CRC, if I use the same code for lengh=128 all is OK. Any idea what is...

View Article

BASCOM-AVR : Any limit to length in Crc16uni function? : REPLY

it works for byte sizes (up to 255).

View Article


BASCOM Project Blog : Watering system Contrioller : REPLY

I have now put together some hardware a 64 x 128 SED LCD and a mega 644 40pin dip using the board below. I have loaded a value into L2 to provide a legitimate time and date to display , a ticking...

View Article

BASCOM-AVR : Any limit to length in Crc16uni function? : REPLY

If you want use CR16uni over bigger things, like eeprom or file, read this topic;...

View Article

BASCOM-AVR : Exporting .exe file with bascom avr : NEWTOPIC

hi i have a problem and i need to export my bascom project to .exe file and run it in my c# application (my project in bascom check crc32 code and just send some data to a port in my system and there...

View Article


BASCOM-AVR Old versions : Exporting .exe file with bascom avr : REPLY

i wonder if you read some of the help? you can not make an EXE , you need to use VB or some other tool like C# for that.

View Article


BASCOM-AVR Old versions : Exporting .exe file with bascom avr : REPLY

look,i had to send data to microcontroller and i wand to add CRC at the end of my data ,but the algorithm for making CRC is vary! my algorithm in c# create some code that is different from my micro's...

View Article

BASCOM-AVR : Any limit to length in Crc16uni function? : REPLY

Thanks Mark for your quick reply. Thanks Evert for the link, this is exectly what I was looking for.

View Article

BASCOM Project Blog : Watering system Contrioller : REPLY

Paulvk, What does the DATE(12) and TIME(12) mean ? Is this a DATE and TIME Array ?

View Article

AVR-DOS : CF-Cards: AVR-DOS & IORDY ? : REPLY

Hello Marc, yes i have evaluated the custom code, it runs but sporadic bytes will still fail. I have made the overall experience, that using of any kind of IRQ driven functions or subs are...

View Article


BASCOM-AVR Old versions : Exporting .exe file with bascom avr : REPLY

see http://avrhelp.mcselec.com/index.html?crc16uni.htm and read the PDF from Ross N. Williams then you can make it in your PC site code

View Article

BASCOM-AVR Old versions : Exporting .exe file with bascom avr : REPLY

Here you can find http://avrhelp.mcselec.com/crc16.htm a sample in VB that works fine with CRC16UNI, shouldn't be to hard to port to C#

View Article


BASCOM Project Blog : Watering system Contrioller : REPLY

These are inbuilt in bascom using the datetime.lbx . DATE(L2) this converts the value of L2 to to give the date, this is why I said in the other posts that you need not worry about hours, min, secs...

View Article

AVR-DOS : CF-Cards: AVR-DOS & IORDY ? : REPLY

I do not understand why using a buffer would be a problem. and the remark about the word? we still use a byte buffer. but since we need a big array, we need words for the pointers. i think i posted...

View Article


BASCOM Project Blog : Watering system Contrioller : REPLY

Thanks a lot.

View Article

BASCOM-AVR : BASCOM Programmer : REPLY

if you choose the manual program option, the programmer window opens and you can chose auto program there. (just click). when done, you can click it again. the window will close once you close it. or...

View Article

BASCOM-AVR : Pulsin Command : NEWTOPIC

Hi All ! I want to use pulsin command. I read manual & find [b:7693829965]ERR variable will be set to 1 in case of a time out. A time out will occur after 65535 unit counts. With 10 uS units this...

View Article