BASCOM-AVR : Xmega TcD0 configuration results : REPLY

$
0
0
Hi Paul, re tipping bucket rain gauge calibration: Take an accurately known volume of water, say 1 litre (1000 mL) and allow it to drip into the gauge at a slow rate and count the tips. Is your gauge a 0.2mL tip model? If yes, expect 5000 counts. Cheers, Ross (ex BoM engineer)